Case Study: Failing Motor under Cover


Here we see a motor driving a transmission.  There were no complaints from the client.   Routine predictive maintenance was offered while the machine was in operation.

1a.JPG

Elevated shaft temperatures at the front  bearing journal were detected and flagged using Infrared Thermal Imaging.

IR 0573.jpg

 Upon removal of safety guard, additional heating was noted also coming from the bearing journal.

3b.jpg

Subsequent removal of safety guard revealed damaged pulley shaft on motor end as well as a broken flange on lower transmission.  Followup inspection of disassembled motor revealed worn shaft and keyway resulting in loose fitting pulley.  Motor bearings were close to failure.  Grease was burnt.

2b.JPG
2c.JPG
IMG 0059.JPG

This problem was flagged and proactively pursued before failure and with minimal downtime !!!